Vivax Metrotech vLoc3-Pro use V3A02T-K02T-COAU

Vivax Metrotech vLoc3-Pro use V3A02T-K02T-COAU

PRODUCT ENQUIRY
Brand: Vivax Metrotech    Code: V3A02-K02T-CN-AU
APN: V3A02T-K02T-COAU   

The 10-Watt broadband transmitter has selectable induction and direct connection frequencies from 98Hz to 200kHz, SD mode (Signal Direction), fault find and true resistance measurement up to 1 Mohm. The two inch by one-inch dot matrix display with LED backlight shows output current, connection type, volts, resistance, frequency, volume, battery condition and high voltage warnings.
The optional Transmitter Link (Tx-Link) installed in the receiver and transmitter, remote operation of the transmitter from the receiver is possible. The range of the radio transmitter link depends on having a clear “line of sight” between receiver and transmitter but is typically around 985 ft./300m. Signal Direction (SD) mode feature verifies if the line being located is the target that the transmitter is connected to.
When a transmitter is connected to a target line, the signal travels along it and finds the easiest way to travel back, usually via the ground and ground stake. However, very often the signal will travel back along adjacent utilities which offer an easier route. As a result, there can be multiple signals radiating from utilities in the area making it difficult to identify the target line. These return signals are typically traveling in the opposite direction than the applied signal. The Signal Direction feature identifies which direction the signal is flowing and hence the target line.
Packaged in a lightweight, rugged, ergonomic IP54 housing, the transmitter provides consistent current output in direct connect, clamp or induction modes and protection against incoming voltages up to 240V.

Classic Mode

Unique in all display modes are the colour codes which give the level of distortion and confidence level.

The Classic Screen has all the functions normally seen on a classic cable locator.

V3A02-C02A-B-AU_07.png

Vector Mode

This view is the Vector screen which is a side view, or cross section view. The inset view is the top pan view. Combined the user has a true 3D view.

Vector mode allows to measure utilities from a location which is offset. This would potentially allow to detect a utility that is located on a busy road from the safe location of a sidewalk.

V3A02-C02A-B-AU_08.png

Transverse Mode

The Transverse Plot screen is used to analyse the field shape at a particular location. This enables the user to get a better feel for the reliability of the data gathered.

Two plots are generated simultaneously

  • Peak response
  • Null response

In non-distorted fields, the peak and null positions should coincide, and the shape of the fields should be symmetrical about the centre line.

V3A02-C02A-B-AU_09.png

Plan Mode

The Plan View screen shows a picture as if you were viewing the line from above the ground. When the blue line in the centre and pointing forward/back you are directly over the line and pointing in the direction of the line.

Red, blue and green colour of the line show the level of distortion and confidence level.

V3A02-C02A-B-AU_10.png

Sonde Locating Mode

The Sonde give a different “Peak” pattern and there are three distinct peaks – a small peak – a large peal - a small peak with two “Nulls” between the peaks. The Sonde is located under the centre of the “large peak”

V3A02-C02A-B-AU_11.png

FEATURES

  • Optional transmitter-to-receiver radio link
  • Lightweight – Only 7.15 lbs. / 3.24 kg with Li-ion battery
  • SD mode for positive location in congested areas
  • AC/DC external power source
  • Built-in AVO meter
BROCHURES
VLOC3 - Brochure
PRODUCT MANUALS
Vivax Metrotech vLoc3-Pro use V3A02T-K02T-COAU - Product Manual

OVERVIEW

The 10-Watt broadband transmitter has selectable induction and direct connection frequencies from 98Hz to 200kHz, SD mode (Signal Direction), fault find and true resistance measurement up to 1 Mohm. The two inch by one-inch dot matrix display with LED backlight shows output current, connection type, volts, resistance, frequency, volume, battery condition and high voltage warnings.
The optional Transmitter Link (Tx-Link) installed in the receiver and transmitter, remote operation of the transmitter from the receiver is possible. The range of the radio transmitter link depends on having a clear “line of sight” between receiver and transmitter but is typically around 985 ft./300m. Signal Direction (SD) mode feature verifies if the line being located is the target that the transmitter is connected to.
When a transmitter is connected to a target line, the signal travels along it and finds the easiest way to travel back, usually via the ground and ground stake. However, very often the signal will travel back along adjacent utilities which offer an easier route. As a result, there can be multiple signals radiating from utilities in the area making it difficult to identify the target line. These return signals are typically traveling in the opposite direction than the applied signal. The Signal Direction feature identifies which direction the signal is flowing and hence the target line.
Packaged in a lightweight, rugged, ergonomic IP54 housing, the transmitter provides consistent current output in direct connect, clamp or induction modes and protection against incoming voltages up to 240V.

Classic Mode

Unique in all display modes are the colour codes which give the level of distortion and confidence level.

The Classic Screen has all the functions normally seen on a classic cable locator.

V3A02-C02A-B-AU_07.png

Vector Mode

This view is the Vector screen which is a side view, or cross section view. The inset view is the top pan view. Combined the user has a true 3D view.

Vector mode allows to measure utilities from a location which is offset. This would potentially allow to detect a utility that is located on a busy road from the safe location of a sidewalk.

V3A02-C02A-B-AU_08.png

Transverse Mode

The Transverse Plot screen is used to analyse the field shape at a particular location. This enables the user to get a better feel for the reliability of the data gathered.

Two plots are generated simultaneously

  • Peak response
  • Null response

In non-distorted fields, the peak and null positions should coincide, and the shape of the fields should be symmetrical about the centre line.

V3A02-C02A-B-AU_09.png

Plan Mode

The Plan View screen shows a picture as if you were viewing the line from above the ground. When the blue line in the centre and pointing forward/back you are directly over the line and pointing in the direction of the line.

Red, blue and green colour of the line show the level of distortion and confidence level.

V3A02-C02A-B-AU_10.png

Sonde Locating Mode

The Sonde give a different “Peak” pattern and there are three distinct peaks – a small peak – a large peal - a small peak with two “Nulls” between the peaks. The Sonde is located under the centre of the “large peak”

V3A02-C02A-B-AU_11.png

FEATURES

FEATURES

  • Optional transmitter-to-receiver radio link
  • Lightweight – Only 7.15 lbs. / 3.24 kg with Li-ion battery
  • SD mode for positive location in congested areas
  • AC/DC external power source
  • Built-in AVO meter

DOWNLOADS

BROCHURES
VLOC3 - Brochure
PRODUCT MANUALS
Vivax Metrotech vLoc3-Pro use V3A02T-K02T-COAU - Product Manual
PROMOTIONS

Redeem Leica Disto

Purchase a Rugby Laser Level and redeem a Leica Disto D1 or D2 FREE - follow the link below to redeem

> Learn More

All-inclusive GIS/GNSS Mapping Kit

Centimetre-grade surveying for everyone, at a great price

> Learn More

End-of-Year Utility Detection Special

vLoc3-Pro utility locator – December PROMO 10% off

> Learn More

Trade In and SAVE!

Trade in ANY Total Station and purchase a Leica ICR80 Robotic Kit from $36,500 ex

> Learn More

BUY THE EQUIPMENT YOU NEED NOW

Defer your first payment for 3 Months*

> Learn More